1、求医学软件MIMICS14破译版本下载
http://www.163disk.com/fileview_1578788.html
2、MIMICS13.0破解版下载?
求MIMICS13.0或14.0以上的下载地址,谢谢
邮箱820213701@qq.com,谢谢了
3、怎么下载Mimics10.1 软件安装包和中文教程
百度:binzi229俱乐部,这里有。
4、英语翻译
Due to long-term injuries, cervical intervertebral disc or bone hyperplasia, emergence, ligament, causing cervical spinal cord thickening, nerve root or vertebral artery pressure, appear a series of clinical syndrome -- the dysfunction, this is a kind of cervical spondylosis tendinosis Daniel to change on the basis of disease. It is common and frequently-occurring diseases among elderly people, even some young people also suffer from the disease.
According to the disease, this paper designs a cervical vertebra, the fusion between vertebral implantation after implantation in the human body vertebra, stabilizing rachis, osteoarthritis, prevent disc fusion of degenerative deformation to a certain extent, restore intervertebral space height.
Based on software mimics, then through rebuilding cervical model establishment, Solidworks software ANSYS software reuse and Solidworks interface import by finite element analysis.
This paper designs the cervical vertebra implantation after spinal reconstruction after the total deformation occurs at the side of the load, and the smallest serrated total deformation occurs in the side constraints, serrated, the maximum equivalent elastic strain and the maximum equivalent stress occurred in the middle surface after partial position, minimum equivalent elastic strain and minimum equivalent stress of serrated next surface.
The cervical vertebral strength between the cervical fusion meets the biomechanical characteristics, but failed to consider when designing bone graft versus discectomy contact window and the ratio of the area, the correct design should guarantee is the window of bone graft can fill the bone, but also to maintain proper contact area, if the contact area small will cause the subsidence effect. And when the design also didn't consider the height, serrated, serrated if too may also occur, causing cervical settlement effect of degenerative deformation, but if the zigzag too low, causes of fusion device, thus not slippage of the height of recovery.
Choose the material of fusion of PEEK also exists many limitations, PEEK materials of fusion is not absorbed into the body, also exist for reoperation placeholder effect, or adjacent segmental surgery, as a foreign body in the cage, still is the potential for the rejection reflects the source, the design, the cage appearance with normal cervical vertebra forms are not detrimental to promote bone fusion.
5、win10系统上下载mimics软件可以下载吗
软件如果是正规软件,WIN10系统肯定是兼容的。
需要下载的话,你通过腾讯电脑管家的软件管理平台即可下载到。
这里提供相当丰富的软件资源:
打开腾讯电脑管家——工具箱——软件管理——宝库
从上图中,你应该不难看出,该平台除了软件下载外,还提供例如软件升级、卸载等多方面的管理功能。
该软件的使用性挺强的。
6、geomagic studio 9或者12下载以及破解,还有mimics 下载以及破解
我有一个 能用 我的电脑是32位的 64的不知道能不能用 你可以试一下 仔细看一下说明 特别注意一下COMMON 文件下的破解 因为不管你的GEOMAGIC安装在哪个盘里面 COMMON文件都在C盘
希望能帮到你 至于源程序 你可以去下试用版的 用这个破解就可以了